K.D. Stadium Lockers Specifications


Download Text Version

K.D. Stadium? Locker Overview

(Knocked Down, or Unassembled)

Penco Stadium? lockers have an open front and perforated sides providing a fully ventilated space for storage of athletic gear or other items. The base model is an open shell with a full width shelf. A security box fastened to the shelf and a foot locker with a hinged, reinforced seat at the base are popular options. They are available in 24" or 33" widths and 18", 21" or 24" depths. K.D. Stadium lockers are 72" high.

STADIUM LOCKER (KD) SPECIFICATIONS MATERIALS

SHEET STEEL: All parts made from prime grade mild cold rolled sheet steel free from surface imperfection, and capable of taking a high grade enamel finish.

FINISHING: Chemically pretreat metal with a six stage cleaning phosphatizing and metal preparation process. Finish coat shall be electrostatically applied powder coat enamel baked on at 350 to 400 degrees. Select colors from manufacturer's minimum standard 21 colors. All lockers shall be painted inside and outside with the same color.

EQUIPMENT: Coat hooks and coat rods are zinc plated. Truss fin head bolts and hex nuts are zinc coated.

FABRICATION GENERAL CONSTRUCTION: Lockers shall be fabricated square, rigid and without warp.

LOCKER FRAME: Locker frame member to be not less than 16 gauge formed to a channel shape. Intermembering parts to be mortised and tenoned and electrically welded together in a rigid assembly capable of resisting strains.

BODY: Bolt spacing in locker body construction not to exceed 9" o.c. All locker body components shall be made of cold rolled steel specially formed for added strength and rigidity and to ensure tight joints at fastening points. Tops & bottoms shall be 16 gauge with three sides formed 90 degrees and the front offset formed to be flush with the horizontal frame member. Bottoms have two reinforcement channels for added strength. Shelves shall be 16 gauge with four sides formed to 90 degrees, the front edge shall have a second bend. Side panels shall be 16 gauge while the back panel shall be 18 gauge.

SHELF: 16 gauge with four sides formed to 90 degrees, the front edge shall have a second bend.

VENTILATION: For maximum ventilation locker has an open front. Side panels are to be perforated with diamond-shaped openings unless otherwise specified.

NUMBER PLATES: Each locker to be supplied with a polished aluminum number plate, 2-1/4" wide x 1" high, with black numerals not less than 3/8" high. Number plates to be attached to the center of shelf with two aluminum rivets.

INTERIOR EQUIPMENT: Each locker is provided with a set of rod holders, one coat rod and two single prong hooks (to be fastened to the back panel).

OPTIONS

SECURITY BOX: 14 gauge lockable door with a 16 gauge side panel. The door is attached to a welded frame with a continuous hinge. The hinge is mounted to door with aluminum rivets. The door is locked through a single point latch with a padlock or built in lock. A lock hole cover plate shall be provided for use with padlocks. Security box door frame to be not less than 16 gauge formed to a channel shape. Vertical members to have an additional flange to provide a continuous door strike. Intermembering parts to be mortised and tenoned and electrically welded together in a rigid assembly capable of resisting strains.

FOOT LOCKER: Front foot locker panel includes single point latch with padlock strike plate and mini louvers. Lid of foot locker has a continuous hinge and also serves as a seat. Opening and closing of the lid is quieted by rubber bumpers mounted to the contact points. The seat lid is strengthened with two reinforcement channels welded to bottom. Two side seat supports are bolted to side panels and inserted in a support tab on the front locker panel for added strength.

SOLID SIDE PANELS: Side panels shall be void of ventilation holes.

BODY: Locker shall be assembled using rivets.

EXECUTION INSTALLATION: Install metal lockers at location shown in accordance with manufacturers instructions for plumb, level, and flush installation.

ANCHOR LOCKERS to the floor and wall 48" on center or less as recommended by the manufacturer.

ADJUST & CLEAN: Adjust doors and latches to operate without binding. Verify that latches are operating satisfactorily.

TOUCH UP: Marred finishes with factory supplied paint.

ACCEPTABLE MANUFACTURERS 1. Penco Products, Inc., Oaks, PA - Stadium Locker

PENCO RESERVES THE RIGHT TO VARY SPECIFICATIONS CONSISTENT WITH ITS POLICY OF CONTINUOUS PRODUCT IMPROVEMENT.

11/11/2004


Material Handling Experts are a call away: 1-888-877-3861

Toll free 7-5 CST in the United States & Canada | Inquiries & Support

Copyright 2008, Cisco-Eagle; All rights reserved. | Privacy Policy

Offices: Dallas, Houston, San Antonio Texas  |  Little Rock, Arkansas  |  Oklahoma City & Tulsa, Oklahoma 

Clients from California to New York, from Florida to Washington - U.S., Canada & Mexico
Cisco-Eagle is Employee Owned, Managed, and Operated | Site Map