{"id":3289,"date":"2013-06-21T06:30:53","date_gmt":"2013-06-21T11:30:53","guid":{"rendered":"http:\/\/www.cisco-eagle.com\/blog\/?p=3289"},"modified":"2023-06-11T18:36:41","modified_gmt":"2023-06-11T23:36:41","slug":"rule-of-thumb-for-pallet-rack-height-to-depth-ratio","status":"publish","type":"post","link":"https:\/\/www.cisco-eagle.com\/blog\/2013\/06\/21\/rule-of-thumb-for-pallet-rack-height-to-depth-ratio\/","title":{"rendered":"How To Get Your Pallet Rack Height-to-Depth Ratio Right"},"content":{"rendered":"<p><img decoding=\"async\" style=\"width: 100%; max-width: 360px;\" src=\"\/\/images.cisco-eagle.com\/blog\/wp-content\/uploads\/2013\/06\/PalletRackLayout.png\" alt=\"pallet rack system\" \/><\/p>\n<p>When designing <a href=\"https:\/\/www.cisco-eagle.com\/category\/1288\/pallet-rack\">pallet racks<\/a>, people tend to pay attention to the easy parts. Beam capacity is straight math; the capacity of a pair of <a href=\"https:\/\/www.cisco-eagle.com\/category\/793\/tubular-pallet-rack-beams\">beams<\/a>, so long as the load is evenly distributed, the <a href=\"https:\/\/www.cisco-eagle.com\/category\/3046\/how-beam-loading-affects-rack-capacities\">load properly positioned<\/a>, and the safety clips are installed, is a reliable number. Upright frame capacities are a more complex, <a href=\"https:\/\/www.cisco-eagle.com\/blog\/2013\/12\/09\/more-is-more-estimating-pallet-rack-upright-capacities\/\">as they rely on vertical spacing between levels<\/a>. Get these factors right, and typically it doesn&#8217;t take an engineer to design a safe and reliable rack system.<\/p>\n<p><!--more--><\/p>\n<p><img decoding=\"async\" style=\"float: right; margin: 10px; width: 100%; max-width: 85px;\" src=\"\/\/www.cisco-eagle.com\/images\/Product\/medium\/RTFBP042240.jpg\" alt=\"pallet rack frame\" \/>But there is another factor that many don&#8217;t understand and often overlook &#8212; <strong>the Height-to-Depth ratio.\u00a0<\/strong><\/p>\n<p>The RMI (Rack Manufacturers&#8217; Institute) defines the height to depth ratio for a rack row as &#8220;the ratio of the distance from the floor to the top beam level divided by the depth of the frame.&#8221; This ratio can&#8217;t exceed 6-to-1. For a standard <a href=\"https:\/\/www.cisco-eagle.com\/product\/156457\/pallet-rack-upright-42d-x-240h\">20&#8242; tall, 42&#8243; deep frame<\/a> with the beam at the top level, the ratio is 5.714 &#8212; an acceptable ratio with normal anchoring. If that same 42&#8243; deep frame was 24&#8242; tall, it would have a dangerous 6.857 ratio. Steps\u00a0such as special anchors and base plates or overhead rack ties may be necessary. Typically at this ratio, professional rack engineers are needed to ensure the rack is safe.<\/p>\n<p>Note that this ratio is designed for a single rack row. Double rows with frame ties may be calculated differently.<\/p>\n<blockquote><p><em>If you&#8217;re buying racks from a catalog or website most all of the commercially offered ones are going to be within the 6:1 ratio, but you should always confirm that you&#8217;re within tolerance before installing racks.\u00a0<\/em><\/p><\/blockquote>\n<h3>Factors for implementing pallet racks within the right height-to-depth ratio<\/h3>\n<div style=\"padding: 20px; border-radius: 15px; border: 2px solid #E4DDDD; margin: 4px 10px 4px 10px; box-shadow: 0 4px 8px 0 rgba(0, 0, 0, 0.2), 0 6px 20px 0 rgba(0, 0, 0, 0.19);\">\n<h4>What overturns a rack?<\/h4>\n<p>According to RMI &amp; ANSI specifications, anchorages should be able to resist an &#8220;overturning force&#8221; of 350 pounds applied against the topmost beam level of an unloaded rack (a lift truck striking a rack as it&#8217;s loading or unloading pallets certainly qualifies).\u00a0If the LRFD method of design is used, this force should be treated as a live load and multiplied by 1.6.<\/p>\n<h4>The effects of anchoring<\/h4>\n<p>You should consult your rack provider\/manufacturer for information on what is considered a normal anchor. It&#8217;s typically included with installation manuals\/drawings for new racks, and those are available online for many rack brands as well. This is usually a 1\/2&#8243; diameter anchor with a proper depth, assuming a non-seismic application.<\/p>\n<h4>Nonstandard applications<\/h4>\n<p>Consult a qualified rack engineer for base plate, ratio, and anchoring standards for seismic zone applications. Another example is outdoor installations, which must be adjusted for wind force. In particular if the load is large and solid, so that it catches wind. This can cause significant stress on the rack, and potential overturns. Also, this ratio can vary, depending on the installation surface, load type, spacing, and even the rack manufacturer. Always consult with your manufacturer to determine a safe operating ratio for your particular rack system.<\/p>\n<\/div>\n<p>&nbsp;<\/p>\n<p><strong>This guide should be used for informational purposes only.<\/strong> Consult a us for exceptionally tall or narrow racks, or any system design you aren&#8217;t confident in, or for which you have questions\/concerns.<\/p>\n<p>For more specification information, see the <a href=\"http:\/\/www.mhi.org\/rmi\/faq\">RMI page<\/a> of the Material Handling Industry website.<\/p>\n<p><strong>Related articles:<\/strong><strong>\u00a0<\/strong><\/p>\n<ul>\n<li><a href=\"https:\/\/www.cisco-eagle.com\/blog\/2015\/11\/16\/structural-vs-roll-form-pallet-racks-a-comparison\/\">Pallet Rack Comparisons: Structural vs. Roll-Form<\/a><\/li>\n<li><a href=\"https:\/\/www.cisco-eagle.com\/blog\/2015\/08\/27\/falling-item-prevention-for-pallet-racks\/\">How to Prevent Items from Falling Off Pallet Racks<\/a><\/li>\n<li><a href=\"https:\/\/www.cisco-eagle.com\/blog\/2014\/06\/05\/5-common-mistakes-people-make-with-pallet-racks\/\">5 Common Mistakes People Make with Pallet Racks<\/a><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>When designing pallet racks, people tend to pay attention to the easy parts. Beam capacity is straight math; the capacity of a pair of beams, so long as the load is evenly distributed, the load properly positioned, and the safety clips are installed, is a reliable number. Upright frame capacities are a more complex, as [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[6],"tags":[],"series":[],"class_list":["post-3289","post","type-post","status-publish","format-standard","hentry","category-pallet-rack"],"acf":[],"aioseo_notices":[],"publishpress_future_action":{"enabled":false,"date":"2027-04-12 06:19:39","action":"change-status","newStatus":"draft","terms":[],"taxonomy":"category","extraData":[]},"publishpress_future_workflow_manual_trigger":{"enabledWorkflows":[]},"_links":{"self":[{"href":"https:\/\/www.cisco-eagle.com\/blog\/wp-json\/wp\/v2\/posts\/3289","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.cisco-eagle.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.cisco-eagle.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.cisco-eagle.com\/blog\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.cisco-eagle.com\/blog\/wp-json\/wp\/v2\/comments?post=3289"}],"version-history":[{"count":34,"href":"https:\/\/www.cisco-eagle.com\/blog\/wp-json\/wp\/v2\/posts\/3289\/revisions"}],"predecessor-version":[{"id":28092,"href":"https:\/\/www.cisco-eagle.com\/blog\/wp-json\/wp\/v2\/posts\/3289\/revisions\/28092"}],"wp:attachment":[{"href":"https:\/\/www.cisco-eagle.com\/blog\/wp-json\/wp\/v2\/media?parent=3289"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.cisco-eagle.com\/blog\/wp-json\/wp\/v2\/categories?post=3289"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.cisco-eagle.com\/blog\/wp-json\/wp\/v2\/tags?post=3289"},{"taxonomy":"series","embeddable":true,"href":"https:\/\/www.cisco-eagle.com\/blog\/wp-json\/wp\/v2\/series?post=3289"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}